+
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV-4x95+1-1.jpg
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV-3x25+2-2.jpg
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV3X95+2-1.jpg
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV3X95+2-2.jpg
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV-4x95+1-2.jpg
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV22-3X120+1-1.jpg
  • 高低压电力电缆_0.6-1kV电力电缆_阻燃电力电缆_ZC-YJV22-3X120+1-2.jpg

Rated voltage 0.6/1kV flame retardant power cable

Flame-retardant power cable [Chinese name] Rated voltage 0.6/1kV flame retardant power cable [rated voltage] 0.6/1KV [executive standard] GB/T19666-2005, GB12706.1-2008 [features] flame retardant cable is characterized by: delay the flame spread along the cable so that the fire does not expand. Because of its low cost, it is a large number of cable varieties used in fireproof cables. Whether it is a single cable or a bundle of laying conditions, the cable is known to burn when the spread of the flame can be controlled within a certain range, so you can avoid the fire caused by the major disasters, thereby improving the fire level of the cable line. [use] this product is suitable for power frequency rated voltage 0.6/1KV and below distribution network or industrial equipment in fixed laying. Commonly used for overhead operations.

Classification:

Flame retardant power cable

Key words:

Cable

Product Description

 

Model

COPPER CORE

Name

Scope of application

ZA-VV

ZB-VV

ZC-VV

Copper conductor PVC insulated PVC sheathed Class A(B, C) flame retardant power cable

It can be laid in indoor, tunnel and pipeline where flame retardant is required.

ZA-VV22

ZB-VV22

ZC-VV22

Copper conductor PVC insulated steel tape armored PVC sheathed Class A(B, C) flame retardant power cable

It is suitable for buried laying when flame retardant is required, but not suitable for laying in pipelines.

ZA-YJV

ZB-YJV

ZC-YJV

Copper conductor XLPE insulated PVC sheathed Class A(B, C) flame retardant power cable

It can be laid in indoor, tunnel and pipeline where flame retardant is required.

ZA-YJV22

ZB-YJV22

ZC-YJV22

Copper conductor XLPE insulated steel tape armored PVC sheathed Class A(B, C) flame retardant power cable

It is suitable for buried laying when flame retardant is required, but not suitable for laying in pipelines.

 

Model

ØZA-VV,ZB-VV,ZC-VV,ZA-VLVV,ZB-VLV,ZC-VLV

ØZA-VV22,ZB-VV22,ZC-VV22,ZA-VLV22,ZB-VLV22,ZC-VLV22

ØZA-YJV,ZB-YJV,ZC-YJV,ZA-YJV,ZB-YJLV,ZC-YJLV

ØZA-YJV22,ZB-YJV22,ZC-YJV22,ZA-YJLV22,ZB-YJLV22,ZC-YJLV22   

Executive standard

ØGB/T19666-2005,GB12706.1-2008

Rated voltage

Ø0.6/1kV

Use

ØThis product is suitable for power frequency rated voltage0.6/1KVAnd the following distribution network or industrial installations in fixed laying. Commonly used for overhead operations.

Code Description

Name

Code

Description

Flame retardant

ZA-/ZB-/ZC-

A/B/CClass flame retardant

Conductor material

T(L)

Copper (Aluminum)

Insulation material

YJ

cross-linked polyethylene

Insulation/Sheath material

V

PVC

Appearance shape

Y

Round

Skin coloring

BK

Black

Crosslinking mode

ST2

two-step silane crosslinking

Armored material

22

Steel tape armored PVC sheath

 

online message

Submit Message