Rated voltage 0.6/1kV fire-resistant power cable

[abbreviation] fire-resistant power cable 【Chinese 】 rated voltage 0.6/1kV fire-resistant power cable [rated voltage] 0.6/1KV [executive standard] GB/T19666-2005, GB12706.1-2008 [Features] The characteristics of fire-resistant cables are: they can maintain normal operation for a certain period of time under the condition of flame combustion, and can maintain the integrity of the line. Fire-resistant cables produce less acid gas smoke during combustion, and their fire-resistant and flame-retardant properties are greatly improved. Especially when burning, accompanied by water spray and mechanical blow, the cable can still maintain the complete operation of the line. [use] suitable for fixed laying in the fire requirements of the cable under fire can still maintain a certain period of time to continue to run, rated voltage 0.6/1KV power transmission and distribution lines. Such as: high-rise buildings, oil fields, power stations, power plants, mines, chemical industry, mines, subways and other occasions requiring high fire conditions, but also emergency power supply, fire pump, elevator communication signal system should be prepared cable, the product has a high fire resistance, in the case of direct combustion of the flame, in a certain period of time (not less than 3h) without short circuit and open circuit fault, ensure that the power supply is continued to maintain lighting and transmit signals, to protect personnel with enough time to evacuate safely, and to help extinguish fires and reduce losses.

Classification:

Fire-resistant power cable

Key words:

Cable

Product Description

 

Model

COPPER CORE

Name

Scope of application

R-v

Copper conductor PVC insulated PVC sheathed fire resistant power cable

Can be laid in the indoor, tunnel and cable trench can not withstand the mechanical external force of the occasion.

R-v22

Copper conductor PVC insulated steel tape armored PVC sheathed fire resistant power cable

Can be laid in the indoor, tunnel, cable trench or buried and other occasions can withstand mechanical external force, but can not withstand large tension.

Ly yjv

Copper conductor XLPE insulated PVC sheathed fire resistant power cable

Can be laid in the indoor, tunnel and cable trench can not withstand the mechanical external force of the occasion.

Ly yjv22

Copper conductor XLPE insulated steel tape armored PVC sheathed fire resistant power cable

Can be laid in the indoor, tunnel, cable trench or buried and other occasions can withstand mechanical external force, but can not withstand large tension.

 

Model

ØR-v,R-v22,Ly yjv,Ly yjv22

Executive standard

ØGB/T19666-2005,GB12706.1-2008

Rated voltage

Ø0.6/1KV

Use

ØIt is suitable for fixed laying that requires the cable to continue to run for a certain period of time under fire, and the rated voltage0.6/1KVThe power is supplied to the transmission and distribution lines. Such as: high-rise buildings, oil fields, power stations, power plants, mines, chemical industry, mines, subways and other occasions requiring high fire conditions, but also emergency power supply, fire pump, elevator communication signal system should be prepared cable, the product has a high fire resistance, in the case of direct combustion of the flame, in a certain period of time (not less3h3) Short circuit and open circuit faults shall not occur, and power supply shall be continued to maintain lighting and signal transmission, so as to ensure that personnel have enough time to evacuate safely, and it is conducive to fire extinguishing and loss reduction.

Code Description

Name

Code

Description

Fire resistance

NH

Fire resistance

Conductor material

T

Copper

Insulation material

YJ

cross-linked polyethylene

Insulation/Sheath material

V

PVC

Appearance shape

Y

Round

Skin coloring

BK

Black

Crosslinking mode

ST2

two-step silane crosslinking

Armored material

22

Steel tape armored PVC sheath

 
 