Halogen-free low smoke power cable with rated voltage of 8.7/15kV
Halogen-free low smoke power cable [Chinese name] rated voltage 8.7/15kV halogen-free low smoke power cable Rated voltage: 8.7/15kV [executive standard] GB/T12706.2-2008, GB/T12706.3-2008, GB/T12666.5-2008 [Features] Halogen-free low-smoke flame-retardant cables are characterized by not only good flame-retardant properties, but also halogen-free, low-smoke halogen-free cable materials, low corrosion and toxicity during combustion, and a very small amount of smoke, thus reducing damage to people, instruments and equipment, and facilitating timely rescue in case of fire, although they have good flame retardancy, corrosion resistance, and minimal smoke concentration. [use] suitable for fixed laying in the fire requirements of the cable under fire can still maintain a certain period of time to continue to run, rated voltage 8.7/15KV power transmission and distribution lines. Such as: high-rise buildings, oil fields, power stations, power plants, mines, chemical industry, mines, subways and other occasions requiring high fire conditions, but also emergency power supply, fire pump, elevator communication signal system should be prepared cable, the product has a high fire resistance, in the case of direct combustion of the flame, in a certain period of time (not less than 3h) without short circuit and open circuit fault, ensure that the power supply is continued to maintain lighting and transmit signals, to protect personnel with enough time to evacuate safely, and to help extinguish fires and reduce losses.
Classification:
Halogen-free low smoke power cable
Key words:
Cable
Product Description
Model COPPER CORE |
Name |
Scope of application |
ROAD-YJY WDZB-YJY WDZC-YJY |
Copper conductor XLPE insulated polyolefin sheathed halogen-free low-smoke flame retardant Class A(B, C) power cable |
Suitable for indoor and outdoor laying, can withstand a certain laying traction, but can not withstand the mechanical external force of the occasion, single-core cable is not allowed to be laid in the magnetic pipe. |
ROAD-YJY23WDZB-YJY23WDZC-YJY23 |
Copper conductor XLPE insulated steel tape armored polyolefin sheathed halogen-free low-smoke flame retardant Class A(B, C) power cable |
Suitable for buried laying, can withstand mechanical external force, but can not withstand excessive tension. |
Model |
ØROAD-YJY,WDZB-YJY,WDZC-YJY ØUPA-YJY23,WEDMB-YJY23,WYC-YJY23 |
||||||||||||||||||||||||||||||
Executive standard |
ØGB/T12706.2-2008,GB/T12706.3-2008,GB/T12666.5-2008 |
||||||||||||||||||||||||||||||
Rated voltage |
Ø8.7/15kV |
||||||||||||||||||||||||||||||
Use |
ØIt is suitable for fixed laying that requires the cable to continue to run for a certain period of time under fire, and the rated voltage8.7/15KVThe power is supplied to the transmission and distribution lines. Such as: high-rise buildings, oil fields, power stations, power plants, mines, chemical industry, mines, subways and other occasions requiring high fire conditions, but also emergency power supply, fire pump, elevator communication signal system should be prepared cable, the product has a high fire resistance, in the case of direct combustion of the flame, in a certain period of time (not less3h3) Short circuit and open circuit faults shall not occur, and power supply shall be continued to maintain lighting and signal transmission, so as to ensure that personnel have enough time to evacuate safely, and it is conducive to fire extinguishing and loss reduction. |
||||||||||||||||||||||||||||||