Halogen-free low smoke power cable with rated voltage of 26/35kV

Halogen-free low smoke power cable [Chinese name] rated voltage 26/35kV halogen-free low smoke power cable Rated voltage 26/35kV [executive standard] GB/T12706.2-2008, GB/T12706.3-2008, GB/T12666.5-2008 [Features] Halogen-free low-smoke flame-retardant cables are characterized by not only good flame-retardant properties, but also halogen-free, low-smoke halogen-free cable materials, low corrosion and toxicity during combustion, and a very small amount of smoke, thus reducing damage to people, instruments and equipment, and facilitating timely rescue in case of fire, although they have good flame retardancy, corrosion resistance, and minimal smoke concentration. [use] suitable for fixed laying in the fire requirements of the cable under fire can still maintain a certain period of time to continue to run, rated voltage 26/35kV power transmission and distribution lines. Such as: high-rise buildings, oil fields, power stations, power plants, mines, chemical industry, mines, subways and other occasions requiring high fire conditions, but also emergency power supply, fire pump, elevator communication signal system should be prepared cable, the product has a high fire resistance, in the case of direct combustion of the flame, in a certain period of time (not less than 3h) without short circuit and open circuit fault, ensure that the power supply is continued to maintain lighting and transmit signals, to protect personnel with enough time to evacuate safely, and to help extinguish fires and reduce losses.

Classification:

Halogen-free low smoke power cable

Key words:

Cable

Product Description

 

Model

COPPER CORE

Name

Scope of application

ROAD-YJY

WDZB-YJY

WDZC-YJY

Copper conductor XLPE insulated polyolefin sheathed halogen-free low-smoke flame retardant Class A(B, C) power cable

Suitable for indoor and outdoor laying, can withstand a certain laying traction, but can not withstand the mechanical external force of the occasion, single-core cable is not allowed to be laid in the magnetic pipe.

ROAD-YJY23WDZB-YJY23WDZC-YJY23

Copper conductor XLPE insulated steel tape armored polyolefin sheathed halogen-free low-smoke flame retardant Class A(B, C) power cable

Suitable for buried laying, can withstand mechanical external force, but can not withstand excessive tension.

 

Model

ØROAD-YJY,WDZB-YJY,WDZC-YJY

ØUPA-YJY23,WEDMB-YJY23,WYC-YJY23

Executive standard

ØGB/T12706.2-2008,GB/T12706.3-2008,GB/T12666.5-2008

Rated voltage

Ø26/35kV

Use

ØIt is suitable for fixed laying that requires the cable to continue to run for a certain period of time under fire, and the rated voltage26/35kVThe power is supplied to the transmission and distribution lines. Such as: high-rise buildings, oil fields, power stations, power plants, mines, chemical industry, mines, subways and other occasions requiring high fire conditions, but also emergency power supply, fire pump, elevator communication signal system should be prepared cable, the product has a high fire resistance, in the case of direct combustion of the flame, in a certain period of time (not less3h3) Short circuit and open circuit faults shall not occur, and power supply shall be continued to maintain lighting and signal transmission, so as to ensure that personnel have enough time to evacuate safely, and it is conducive to fire extinguishing and loss reduction.

Code Description

Name

Code

Description

Halogen-free low smoke

Wd

Halogen-free low smoke

Flame retardant

ZA-/ZB-/ZC-

A/B/CClass flame retardant

Conductor material

T

Copper

Insulation material

YJ

cross-linked polyethylene

Insulation/Sheath material

Y

Polyethylene

Appearance shape

Y

Round

Skin coloring

BK

Black

Crosslinking mode

ST2

two-step silane crosslinking

Armored material

23

Steel tape armored polyethylene sheath

 

 

 